Table 2 Clinical data

From: Study on the efficacy of 3D printing technology combined with customized plates for the treatment of complex tibial plateau fractures

 

Experimental group

Control group

p

Surgical time(min)

75.27 ± 15.98

102.82 ± 21.11

<0.001

Intraoperative blood loss(ml)

129.32 ± 25.32

158.18 ± 33.61

0.002

Fluoroscopy sessions

6.50 ± 2.09

11.32 ± 3.50

<0.001

Placement accuracy

90.9%(20/22)

71.4% (15/22)

0.132

Preoperative preparation time(days)

5.36 ± 0.79

3.82 ± 0.85

<0.001

Length of hospital stay(days)

9.95 ± 2.48

7.64 ± 2.28

<0.001

Fracture healing time(weeks)

13.45 ± 1.44

13.86 ± 1.64

0.388

Follow-up duration(months)

15.27 ± 2.39

15.36 ± 2.44

0.901