Table 5 Data of four groups of models in different conditions

From: Finite element analysis of retrograde superior ramus screw of pubis for the treament of pelvic anterior ring fracture

Model

Engineering condition

Overall model

Internal fixation

Maximum displacement(×10− 3mm)

maximum V-M stress value(MPa)

Maximum displacement(×10− 3mm)

maximum V-M stress value(MPa)

1

Load in vertical direction

45.158

23.502

26.625

12.685

A-P compression

262.66

38.323

151.55

21.225

lateral compression

995.93

79.129

325.88

79.129

2

Load in vertical direction

55.214

24.952

33.021

19.683

A-P compression

251.72

29.668

149.75

20.304

lateral compression

947.92

86.933

171.56

86.933

3

Load in vertical direction

231.61

526.77

71.38

185.63

A-P compression

261.93

44.334

185.05

44.334

lateral compression

1055.0

533.62

298.42

247.68

4

Load in vertical direction

51.123

22.419

30.651

16.06

A-P compression

232.79

43.476

147.32

18.316

lateral compression

884.87

97.794

179.99

97.794