Skip to main content

Table 2 Anatomic characteristics of specimen 1 and primary data evaluation of manual bone cement injection

From: Safety and feasibility of a smart assistive bone-cement injection system: a cadaveric study

 

BL (mm)

BW (mm)

BH (mm)

Fluoroscopy times

Cement time (s)

Cement (mL)

Cement leakage

T8

25.69

27.74

16.15

7

185

3.9

No

T9

26.11

28.42

16.84

8

165

4.6

No

T10

26.80

30.25

18.43

5

146

3.7

Yes

T11

27.05

31.20

19.20

6

140

4.5

No

T12

28.78

33.88

19.38

8

178

3.8

No

L1

27.21

36.94

23.17

9

188

6.3

Yes

L2

28.93

37.98

22.53

6

180

6.0

No

L3

29.66

39.39

21.65

7

168

6.2

Yes

L4

31.05

43.21

22.21

4

138

6.6

Yes

L5

32.78

44.61

22.41

7

155

6.8

No

  1. BL: body length; BW: body width; BH: body height